test 513
3Com WX-4400 Bootstrap/Bootloader
Version 3.0.2 Release
Compiled on Wed Sep 22 09:18:47 PDT 2004 by
Bootstrap 0 version: 3.1 Active
Bootloader 0 version: 3.0.2 Active
Bootstrap 1 version: 3.1
Bootloader 1 version: 3.0.1
WX-4400 Board Revision: 2.
WX-4400 Controller Revision: 5.
WXA30001.Rel 8863722 bytes
BOOT Index: 0
BOOT TYPE: c
DEVICE: boot0:
FILENAME: default
FLAGS: 00000000
OPTIONS: run=nos;root=md0a
See Also
“boot” on page 501
test Displays or changes the state of the poweron test flag. The poweron test
flag controls whether a WX performs a set of self tests prior to the boot
process.
Syntax
test [ON | on | OFF | off]
ON — Enables the poweron test flag.
on — Same effect as ON.
OFF — Disables the poweron test flag.
off — Same effect as OFF.
Defaults — The poweron test flag is disabled by default.
Access — Boot prompt.
History — Introduced in MSS Version 3.0.