EasyManua.ls Logo

3Com 3CRWX120695A - Page 220

3Com 3CRWX120695A
570 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
220 CHAPTER 5: CONFIGURING WX SYSTEM AND ADMINISTRATIVE PARAMETERS
Notice — Events that can cause system problems have occurred.
These are logged for diagnostic purposes.
Info — Informational messages only. No problems exist.
Debug — Output from debugging.
The default severity level is Error.
The debug level produces a lot of messages, many of which can appear
to be somewhat cryptic. Debug messages are used primarily by 3Com for
troubleshooting and are not intended for administrator use.
3 Configure logging to the console:
a To specify that logging messages be sent to the console, select
Enabled. Clear Enabled to disable the logging of messages to the
console.
b In the Severity Filter list, select the lowest level of severity of the event
or condition to be logged (see the list in step 2).
The default severity level is Error.
4 Configure logging to the current login session:
a To specify that logging messages be sent to the current login session,
select Enabled. Clear Enabled to disable the logging of messages
sent to the current login session.
b In the Severity Filter list, select the lowest level of severity of the event
or condition to be logged (see the list in step 2).
The default severity level is Info.
5 Configure trace logging:
a To enable trace logging, select Enabled. Clear Enabled to disable
trace logging.
b In the Severity Filter list, select the lowest level of severity of the event
or condition to be logged (see the list in step 2).
The default severity level is Debug.
c In the Maximum Size box, specify the maximum size for the trace log
(1 to 50 MB). The default is 1 MB.

Table of Contents

Other manuals for 3Com 3CRWX120695A