294 CHAPTER 7: CONFIGURING AUTHENTICATION, AUTHORIZATION, AND ACCOUNTING PARAMETERS
4 In the Timeout box, specify how long WX switch must wait (1 to 65,535
seconds) for a RADIUS server to respond before retransmitting. The
default is 5 seconds.
5 In the Retry Count box, specify the number of transmission attempts
(1 to 100) for a RADIUS request. The default is 3.
6 In the Dead Time box, specify the amount of time (0 to 1440 minutes)
that must elapse before the WX switch attempts to reach an
unresponsive RADIUS server. The default is 0 minutes.
When the dead time is set to 0, and there are two or more RADIUS
servers in a RADIUS server group, authentication starts with the first
server in the group, unless there are two or more RADIUS servers and
load sharing is configured, in which case authentication starts by trying a
server in round-robin style.