1-8
[Sysname] snmp-agent usm-user v3 managev3user managev3group authentication-mode md5 passmd5
privacy-mode des56 cfb128cfb128
# Set the VLAN-interface 2 as the interface used by NMS. Add port Ethernet 1/0/2, which is to be used
for network management, to VLAN 2. Set the IP address of VLAN-interface 2 as 10.10.10.2.
[Sysname] vlan 2
[Sysname-vlan2] port Ethernet 1/0/2
[Sysname-vlan2] quit
[Sysname] interface Vlan-interface 2
[Sysname-Vlan-interface2] ip address 10.10.10.2 255.255.255.0
[Sysname-Vlan-interface2] quit
# Enable the SNMP agent to send traps to the NMS whose IP address is 10.10.10.1. The SNMP
community name to be used is public.
[Sysname] snmp-agent trap enable standard authentication
[Sysname] snmp-agent trap enable standard coldstart
[Sysname] snmp-agent trap enable standard linkup
[Sysname] snmp-agent trap enable standard linkdown
[Sysname] snmp-agent target-host trap address udp-domain 10.10.10.1 udp-port 5000 params
securityname public
Configuring the NMS
Authentication-related configuration on an NMS must be consistent with that of the devices for the NMS
to manage the devices successfully. For more information, refer to the corresponding manuals of
3Com’s NMS products.
You can query and configure an Ethernet switch through the NMS.