24 CHAPTER 2: INSTALLING THE SWITCH
Figure 4 Fitting a Bracket for Rack-Mounting
3 Insert the two screws and tighten with a suitable screwdriver.
You must use the screws supplied with the mounting brackets. Damage
caused to the unit by using incorrect screws invalidates your warranty.
4 Repeat steps 2 and 3 for the other side of the Switch.
5 Insert the Switch into the 19-inch rack and secure with suitable screws
(not provided). Ensure that ventilation holes are not obstructed.
6 Connect network cabling.
7 Finally place a unit information label on the unit in an easily accessible
position. The unit information label shows the following:
3Com product name of the Switch
3Com 3C number of the Switch
Unique MAC address (Ethernet address) of the Switch
Serial number of the Switch
You may need this information if you contact 3Com Technical Support.