1-6
Field Description
Advertise :
Advertise ACK :
Heart Beat :
Left Check :
Right Check :
Auto update :
Numbers of various negotiation packets:
z Advertise
z Advertise ACK
z Heart Beat: Heat beat packet, which is used
to advertise topology connections to the units
by the FTM-Master after convergence.
z Left Check: Handshake packets between
neighbors. They are sent from the left port
and used to monitor the state of the
neighbors periodically.
z Right Check: Handshake packets between
neighbors. They are sent from the right port
and used to monitor the state of the
neighbors periodically.
z Auto update: Number of auto update packets
sent and received
You can use the above numbers to analyze
whether the transmission of data among fabric
units is normal, and thus to judge whether the
fabric operates normally.
Left Port : Index = 255, IsEdge = 0
Right Port : Index = 25, IsEdge = 0
Indexes of the left and right ports:
z IsEdge: Whether the device is at either end of
a bus topology XRN fabric in which the
number of member devices has reached the
upper limit.
z 0: No
z 1: Yes
Units Num Left : 1
Units Num Right : 2
Number of units (both directly-connected and
subtending units) connected to the port,
including the device itself.
z 1: The left port has no connected unit
z 2: The right port connects to one unit
Units Num Backup: 2 Total number of units in a fabric
# Display the topology database information of the current fabric.
<Sysname> display ftm topology-database
Total number of units in fabric : 8, My Unit ID : 4
UID CPU-Mac Priority Fabric-Port Board-ID A/M
1 000f-e20f-5002 10 Left/ 1 A
2 000f-e20f-5132 10 /Right 1 A
3 000f-e20f-5252 10 Left/ 1 A
*4 000f-cbb7-3264 5 /Right 1 M
5 000f-cbb7-2142 10 Left/ 1 A
6 000f-e20f-8922 10 /Right 1 A
7 000f-cbb7-2260 10 Left/ 1 A
8 000f-cbb7-2734 10 /Right 1 A
Table 1-2 display ftm topology-database command output description
Field Description
UID Unit ID