EasyManua.ls Logo

3M DBI SALA 7241420 - INSPECTION; Inspection Frequency; Inspection Records; Handling Defects

3M DBI SALA 7241420
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18
4.0 INSPECTION
4.1 INSPECTION FREQUENCY: The 8mm HLL Permanent Horizontal Lifeline must be inspected by the Certi ed Installer
after installation and at the intervals de ned in Section 2. Inspection procedures are described in the “Inspection
and Maintenance Log” (Table 2). Inspect all other components of the Fall Protection System per the frequencies and
procedures de ned in the manufacturer’s instructions.
4.2 INSPECTION RECORDS: Results of each Certi ed Installer inspection should be recorded on copies of the Inspection and
Maintenance Log. The date for the next required Certi ed Installer inspection should be recorded on the System Label.
RFID Tag: Some Horizontal Lifeline (HLL) systems are equipped with a Radio Frequency Identi cation (RFID) Tag.
The RFID Tag can be used in conjunction with a Handheld Reading Device to simplify inspection and inventory control
and provide records for you fall protection equipment. Contact 3M or visit 3M.com/FallProtection for details.
4.3 DEFECTS: If inspection reveals an unsafe or defective condition, do not use the 8mm HLL System. Follow employer
recommended Lockout/Tagout procedures to remove the system from service and contact the 3M Certi ed Installer for
inspection and service. Do not attempt to repair the system. Only 3M or parties authorized in writing by 3M may make
repairs to this equipment.
4.4 PRODUCT LIFE: The functional life of the 8mm HLL system is determined by work conditions and maintenance. As long
as the product passes inspection criteria, it may remain in service.
5.0 MAINTENANCE, SERVICING, STORAGE
5.1 CLEANING: Periodically clean the systems metal components with a soft brush, warm water, and a mild soap solution.
Ensure all components are thoroughly rinsed with clean water after cleaning.
Contaminants: Although highly resistant to chemicals and environmental conditions, avoid contaminating the 8mm
HLL and Travelers with acids, bitumen, cement, paint, cleaning uids, etc. If the equipment contacts acids or other
caustic chemicals, remove from service and wash with water and a mild soap solution. Inspect per the “Inspection and
Maintenance Log” (Table 2) before returning to service.
5.2 SERVICE: Only 3M or Certi ed Installers authorized in writing by 3M Fall Protection may make repairs to this equipment.
If the 8mm HLL System has been subject to fall force or inspection reveals an unsafe or defective conditions, remove the
system from service and contact 3M Fall Protection or a 3M Certi ed Installer regarding replacement or repair.