Ascotel IntelliGate 2025/2045/2065
204 Identification Elements Part 2
Tab. 2.15: Example 4: Creating and presenting subscriber C’s CLIP number
Call to the Public Network via a Gateway PINX with Overflow Routing and
"Automatic CLIP = no"
Subscriber B (330) on PINX 2 calls subscriber F on the public network via PINX 3
as all the available communication channels between PINX 2 and PINX 1 are busy.
PINX 3 does not have a DDI number for subscriber B.
"Automatic CLIP = no" is set in the configuration subscriber of subscriber B. The
CLIP settings of the subscriber configuration are used:
• CLIP number = 55 555 55 53
• NPI = E.164
• TON = national
Fig. 2.24: Example 5: Subscriber B calls subscriber F (excerpt from Fig. 2.19)
Step CLIP number NPI TON Description
1 340 PNP level 0 Subscriber C → PINX 2
• There is no suitable DDI number.
2 50340 PNP level 1 PINX 2 → PINX 3
3 50340 PNP level 1 PINX 3
• There is no suitable DDI number.
4 60 Unknown Unknown PINX 3 → Exchange
• The CLIP number entered in the trunk group con-
figuration is sent to the public network.
5 066 666 66 60 Exchange → Subscriber F
• Presentation on the terminal
B
330
330
55 555 55 53
055 555 55 53 022 222 22 22
F
Source PINX Gateway PINX
55 555 55 53
Region 60Region 50
55 555 55 53
haz0690aaena0
PINX 2 PINX 3