EasyManua.ls Logo

Aastra Ascotel IntelliGate 2025 - Page 295

Aastra Ascotel IntelliGate 2025
1014 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Ascotel IntelliGate 2025/2045/2065
Part 2 Call Routing 295
Routing the call
[1] One and the same trunk group cannot contain both analogue and digital network interfaces.
Fig. 2.70: Routing a call to the public network
Tab. 2.36: Setting the routing parameters
Parameter Parameter value
Subscriber configuration SC 220:
Route 1 (route reference number)
External digit barring One digit barring each for switching position 1, 2 and 3
Route 1:
Trunk groups 1 (reference number of one or more trunk group(s))
Outgoing connections Number of connections allowed simultaneously
Digit barring Yes (poll digit barring)
Numbering plan identifier NPI E.164
Trunk group 1:
Network interfaces Network interfaces of this trunk group
Network type Public
1)
1)
Not relevant for trunk groups with analogue network interfaces
Protocol DSS1
1)
Trunk group 2 (PSS1)
<- Trunk group 1
Route 1
Route 2
Subscriber config.
Call distribution 1
220
PISN
1/n
Subscriber config.
Call distribution 3
220
3/n
Subscriber
Network
connections
KT line
T
T2
Se
Trunk group 1 (DSS1)
<- Network
connections
<- Trunk group 2<- Network
connections
Subscriber 220
<- Route 1
<- KT route 1
<- KT route 2
Exchange
T
[1]
T2
0 333 33 33
333 33 33
a/b
PISN subscriber 330
<- Call number
<- Route 2
PINX 1
PINX 1
PINX 2
haz0731aaena0

Table of Contents

Related product manuals