Ascotel IntelliGate 2025/2045/2065
Part 2 Call logging (CL) 373
Digit barring if output is blocked
If for whatever reason the printer cannot print or the PC cannot receive data (see
"Printer faults", page 384), the next 300 calls (System 2025 / 2045) or 1000 (Sys-
tem 2065) are stored internally in the PBX. After that, the selected digit barring
(e.g. 1) becomes active. Then only the numbers enabled by the digit barring can
be dialled.
Fig. 2.125: Situation if output is blocked
7.2.2 Surcharge calculator
The surcharge calculator is used to assess surcharges on top of the official call
charges.
Four independent surcharge calculators can be configured and allocated to the
cumulative counters of the subscribers or rooms. Call charges are indicated to
each subscriber (only on system terminals with a display) while the call is in
progress. If the subscriber has been allocated a surcharge calculator, the call
charges displayed include surcharges.
The cost curve of a surcharge calculator is defined by the basic surcharge and
4 cost ranges.
For each of the 4 ranges the user can specify a factor with which the call charges
in the corresponding range limits are multiplied.
-.;.-., -.,-.
,-.,-., .,
,-.-., -.,-.,
max.
2
1
External digit barring ……1……
1
Service and
emergency numbers
all disabled (s)
all enabled (f)
F1 111 S1 ……
F2 116 S2 ……
F3 117 S3 ……
F4 118 S4 ……
F5 140 S5 ……
F6 144 S6 ……
F7 …… S7 ……
F8 …… S8 ……
F9 …… S9 ……
F10 …… S10 ……
Paper out
Paper jam
Mains failure
Printer fault
The charge data of a
maximum number of calls
are stored
if maximum
reached…
becomes activ!