Ascotel IntelliGate 2025/2045/2065
384 Call logging (CL) Part 2
Output when used in a hotel
When determining the output concept, remember to take note of the comments
in "Menu and operating concept with AIMS", page 555.
Setting the page length
In principle, the page length can be set individually for all output types. If, how-
ever, only one output device is connected, the page length set for "Service
printer" output type will apply.
7.5 Printer faults
If it is not possible to print on the CL printer for at least one minute (e.g. paper
out), an event message will be triggered in the PBX. If the interruption can be
remedied immediately, there are no further repercussions, as the call data is
stored temporarily in a buffer. After a maximum number of calls (2025 / 2045 sys-
tem: 300, (System 2065) 1000) the emergency digit barring is activated. The
emergency digit barring affects all the subscribers throughout the system, with
the exception of the Operator Console. This feature restricts the dialling options
in the event of a printer jam. Once the fault is remedied, normal digit barring is
activated once again.
Tab. 2.83: Buffering when output is blocked
Note:
The PBX can only detect printer faults if the printer is operated with RTS/
CTS DSR/DTR flow control (hardware handshake mode).
Call Call data
1
.
.
.
50%
A corresponding event message is generated
ICL data is buffered
OCL data is buffered
.
.
.
max.
OCL data is buffered
ICL data is no longer buffered
max. +1
.
.
.
Emergency digit barring is activated