Part 2 Call logging (CL) 387
Data field formatting
A data field can be formatted to be right or left justified and padded with leading
numbers or blank spaces. Tab. 2.86 shows the symbols used to describe the data
fields in Tab. 2.87.
Tab. 2.86: Symbols used for describing the data field formatting
Data field length
The length of a data field can be permanently defined or remain variable up to a
maximum length.
7.6.2 Data fields of the PC format
Tab. 2.87 shows the complete data record of a PC5 output. The data fields are
listed in their task sequence.
Tab. 2.87: PC5 format
Symbol Meaning
I- Left justified
-I Right justified
0 Padded with "0" up to the permanently defined data field length
SP Padded with spaces up to the permanently defined data field length
Data field Name Data format Formatting Length Offset
Start of data record:
Horizontal tab (HT) 1 0
Subscriber number NO i SP -I 12 1
Cost centre number CC i SP -I 9 14
Sort character SC i 0 -I 3 24
Date of start of connection DATE yymmdd 0 -I 6 28
Time of start of connection TIME hh:mm 0 -I 5 35
Duration of connection DURATION hhHmmMss 0 -I 8 41
Call charges CHARGES ddddddd.dd SP -I 10 50
Number of metering pulses METPUL i 0 -I 5 61
Channel group / trunk card / network
interface number
EXCH cbbpp 0 -I 5 67
Caller identification 1 ID1 i SP -I 20 73
Caller identification 2 ID2 i SP -I 20 94
Destination number 1 DEST1 i SP -I 40 115

Table of Contents