7.6.3 Examples of the PC5 output on a stand-alone PBX
Outgoing calls to the public network
A business call is set up with the public network using subscriber dialling. The digit
sequence 010 is therefore entered as the sort character. Least Cost Routing func-
tion is deactivated.
Fig. 2.137: Outgoing call to the public network
Tab. 2.94: OCL output for an outgoing call to the public network
Incoming calls from the public network
Answered calls
All answered calls have a call duration greater than 0. The "Time" and "Date"
fields indicate when the call was set up. The "TTA" field specifies the duration of
the ringing phase. The sort character is 321.
NO CC SC DATE TIME DURATION CHARGES METPUL EXCH
201 010 060798 10:20 00H14M05 1.00 00010 00101
ID1 ID2 DEST1 DEST2 TTA SEQ.NO. SERIAL NO.
01 6242111 6242111 0001
Int. No. 201
DDI: 01
A
032 624 22 00
.
.
09
B
032 624 21 11