Ascotel IntelliGate 2025/2045/2065
658 Planning DECT systems Part 3
A list of radio units appears:
Top line: Identification, last digit – field strength in dBµV
Bottom line: "go" (Foxkey), starts the measurement
Selected radio units / number of visible radio units "
¥", selection of radio units
(scrolling).
This display is used to provide an overview of the radio units to be received.
To display only the field strength of radio unit A, you need to select A from the
list:
Press the "M" key
Press the Foxkey repeatedly at "
¥" until the identification corresponding to
radio unit A appears on line 1.
Then press "Tick"; a dot appears next to "Tick".
Press the "M" key
The field strength of radio unit A appears
Press the Foxkey at "go": The measurement starts.
Check:
The measured value should be >60 in the immediate vicinity of the test radio unit.
Display radio units A and B:
Press "M" -- back to the overview
Press "M" -- Tick mode
Tick radio unit B
Press "M" and then the Foxkey at "go" -- both radio units are displayed.
The field strengths of A and B can now be measured simultaneously and entered
on the plan.
Tab. 3.30: The measured values and what they mean
A value of at least 40 should be measurable in the overlap area of the two radio
units.
Value Meaning
> 60 Very good quality
40 to 60 Good quality
40 to 60 Mostly good quality. Crackle interference is possible depending on the position, especially
when moving. A check with the test handset is recommended
25 to 30 Still accessible but stronger interference is possible, check with test handset. A good call
quality will be possible during operation provided the user stands still.
below 25 No stable connection possible.