2 Mounting the PBX
The PBX can be both wall-mounted or installed vertically inside a 19" system cab-
inet. A special rack version is available for horizontal mounting in a 19" system
cabinet (see "Rack version Ascotel IntelliGate", page 712).
2.1 PBX location
When positioning the PBX take note of the location requirements in Tab. 4.1.
Tab. 4.1: PBX location requirements
Location requirement
Location in general Easily accessible and with adequate lighting
Heat radiation Do not position the PBX in direct sunlight or near heating sources
EMC Do not position the PBX in strong electromagnetic fields of radiation
(e. g. near x-ray equipment, welding equipment, etc.)
Convection Observe the clearance requirements with the PBX (see Fig. 4.1 or Fig. 4.2)
Provide ventilation slots of approx. 600 cm
2
each at the top and bottom of built-
in cabinets
Environment Room temperature 5...35 °C
Relative humidity 30.0.80%, non-condensing