744 Connecting the PBX Part 4
6.1 Direct connection
Direct connection is via quad two-conductor pillar terminal blocks. The pillar ter-
minal blocks are supplied with the PBX; they can also be ordered in packs from
the system supplier.
Suitable connecting wire:
• Solid copper conductor
• Conductor diameter 0.4 to 0.8 mm
Connecting the PBX
[1] = Pin 1
[2] The apertures above one another are electrically connected.
Fig. 4.28: Connecting and plugging in a quad two-conductor pillar terminal block
OI-2DOOR 1
2)
10
3)
2025 / 2045(MBS) 2
4)
7
2065 (MBL) — 1
1)
8 contacts blank
2)
Only if a second door intercom is being used.
3)
If all the functions of the first door intercom are being used.
4)
4 contacts blank
Expansion card / mainboard Number of 16-pin connectors for
16-wire cable
Number of quad
two-conductor pillar terminal
blocks
6-7
mm
1
2
3
4
1
3
4
2
[1]
[2]