The max. length of an AD2 connection via secondary, tertiary and patch cables
must not exceed 100 m in compliance with UGV guidelines. Both patch cables
together can be a max. 10 m.
S-bus crossover
On the S-bus user-network interface the pairs c/d and e/f are wired in a different
sequence on an RJ45 connector than on the UBC / ISDN network side.
Observe the following installation rules:
• Always terminate the bus extremity with 2 x 100 Ω (0.25 W, 5%)!
• Carry out the necessary crossover on the subscriber side of the PBX.
• If the subscriber cabling is integrated into the installation of a universal building
cable installation (UBC), cross over the S bus as shown in Fig. 4.34.