EasyManua.ls Logo

Aastra Ascotel IntelliGate 2025 - 7.3.1.3 Cable Requirements; 7.3.1.4 Basic access T, network-side; 7.3.1.5 Basic access in the private leased-line network

Aastra Ascotel IntelliGate 2025
1014 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Ascotel IntelliGate 2025/2045/2065
Part 4 Cabling interfaces 755
7.3.1.3 Cable Requirements
Tab. 4.20: Cable requirements for the basic access (NT1 to PBX)
A prefabricated cable (NT-side with RJ45) is available as an option.
7.3.1.4 Basic access T, network-side
[1] Do not connect power supply NT1
[2] Do not fit the jumper
Fig. 4.39: Basic access on NT1
7.3.1.5 Basic access in the private leased-line network
Fig. 4.40: Basic access S external, networked with copper line
Core pairs x cores 1 x 4 or 2 x 2
Stranded yes
Wire diameter, core 0.4…0.6 mm
Screening recommended
Characteristic impedance < 125 (100 kHz), < 115 (1 MHz)
Wave attenuation < 6 dB/km (100 kHz), < 26 dB/km (1 MHz)
Near / crosstalk attenuation > 54 dB/100 m (1 kHz bis 1 MHz)
Exchange
NT1
230 VAC
PBX
c
a
b
d
e
f
[2]
[1]
UT
c
d
e
f
T
haz0621aaenb0
max. 1'000 m
S external
T
PINX 1 PINX 2
Copper line
4
haz0624aaena0