Ascotel IntelliGate 2025/2045/2065
Part 5 Enabling local access 847
3.1.3 Updating passwords
Any password on any given authorization level can be replaced by a new pass-
word on that same level.
If a password on levels 1 to 3 is lost, it is possible with AIMS via V.24 to log into
the configuration using the password-free access via the HEX rotary switch – see
section below – and then configure a new password.
The password for authorization level 4 can only be changed by Support.
3.2 Access via the HEX rotary switch on the mainboard
The HEX rotary switch on the mainboard provides a password-free local access
(only via AIMS and V.24) to the menus of authorization level 3.
• Allow access:
Turn HEX rotary switch to 5.
• Bar access:
Turn HEX rotary switch back to 0 (or 2 or B).
Password-free access with the System Assistant on the Office 45 is also possible.
There is no password-free access for remote maintenance.
3.3 Automatic exit from the configuration
The PBX will interrupt access to the system configuration if you do not make any
changes to a parameter value or do not make use of the navigation system during
the set disconnect time ("View: Options" under "Online Connections").
3.4 Access log
To be able to retrace access activities and access attempts made to the configura-
tion, the PBX records the access log in accordance with authorization level 1 to 4.
The entries contain the following information:
• Date, Login time and duration of maintenance
• CLIP (Calling Line Identification Presentation)