EasyManua.ls Logo

Aastra Ascotel IntelliGate 2025 - 3.5 Function test of the Ascotel Voice Mail System; 3.6 Checking the logging of call data and call charges; 3.7 Checking the data service; 3.7.1 Data transmission on the B channel

Aastra Ascotel IntelliGate 2025
1014 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Ascotel IntelliGate 2025/2045/2065
Part 6 Function check 875
3.5 Function test of the Ascotel Voice Mail System
Checkpoints:
Auto Attendant
Announcement texts
Notification on the terminal
3.6 Checking the logging of call data and call charges
The logging of call data (OCL / ICL) and call charges (ICC) is enabled only when a
terminal is connected.
Checkpoints:
Are the call charges displayed on the terminal?
This feature depends on the network provider.
Is the output format (PC5, 4, 3, etc.) correct?
(see "Output formats", page 385).
3.7 Checking the data service
3.7.1 Data transmission on the B channel
Test procedure
Set up connections to various data services via the ISDN network using known
data service numbers.
Test services that allow both outgoing and incoming communication (e.g. fax,
TA) in incoming mode also (with and without direct dialling).
Check the configuration of the data service table.

Table of Contents

Related product manuals