4 Operations supervision
4.1 Event message concept
The PBX generates an event message every time an event or error occurs. The
event tables in the Fault & Maintenance Manager are used to specify how often
an event message of a particular type may be generated over a given time period
before the event message is sent to the allocated signal destinations.
The Fault & Maintenance Manager has 4 event tables that can be allocated to 4
signal destinations:
F = Frequency
T = Time period
Fig. 7.8: Distribution principle for an event message
1
Event
tables
Signal
destinations
Terminal
External signal
destination
Local signal
destination
PC with SEM on
TA / ISDN Gateway
System terminal
with display in
message group
Printer / PC with
SEM on V.24 Main-
board / PA
PC with SEM on
TA / ISDN Gateway
PC with SEM an
Ethernet interface
Event message
Event log
(AIMS Fault & Mainte-
nance Manager)
Event messages
System failures
Mains voltage
failures
Card failures
Event type H Z
2
Event type H Z
3
Event type H Z
4
Event type H Z
haz1191aaena0