914 Operations supervision Part 7
4.1.1 Event types
Tab. 7.6: Event types, in alphabetical order
Event / error message Trigger condition Details
ACD server out of service ACD server defined as destination but not
responding.
Date, time
Active radio unit defective Radio unit not responding Card number, port number,
date, time
Card out of service A card previously in operation has stopped
functioning.
Number of the expansion slot,
date, time
CL Printer Jam No response from system printer for past
4 minutes
Printer out of paper or switched off
V.24 interface, interfaces/card
number, port number, date,
time
DECT channels on DSP-0x
overloaded
DECT channels on DSP-0x overloaded Date, time
ESME unobtainable The LAN connection between the SMSC
and the ESME is interrupted
Date, time
External signal destination
missing
External signal destination not automati-
cally reachable
0: Busy / 1: Not available / 2:
Barred / 3: Undefined, date,
time
External SMS gateway
unobtainable
External SMS gateway unobtainable by
network provider or incorrectly configured
Date, time
ICC overflow Individual cumulative counter or cost cen-
tre counter overflow
Subscriber number, cost centre,
exchange line, room number,
date, time
Internal signal destination
missing
Local output blocked or not available 0: Busy / 1: Not available / 2:
Barred / 3: Undefined, date,
time
LCR on alternative network
provider
Automatic switch from primary network
provider to secondary network provider
using LCR function
Provider ID, date, time
Local network supply error
on the radio unit
Local power supply of an SB-8 radio unit
failed or unavailable
Card number, port number,
date, time
Mains voltage failures Event message once mains power is
restored
Mains power has failed more frequently
than entered in the trigger table
Date, time
Malfunction With 3-digit error ID Hardware error during
self-test (for more details see Tab. 7.25)
With 5-digit error ID: General error during
operation (for more details see Tab. 7.7)
Error ID, date, time
No response from network No answer to call setup on T / T2 interface Port number of the exchange
line circuit, date, time

Table of Contents

Related product manuals