Ascotel IntelliGate 2025/2045/2065
944 Operations supervision Part 7
Errors that concern partial functions overwrite the standard output of the main-
board's 7-segment display for 10 seconds. Errors that lead to a restart are dis-
played permanently.
Error messages are characterized by the letter E (= error), followed by a three-digit
error code. The individual digits appear one after the other on the single-digit sta-
tus display of the mainboard (7-segment display with decimal point).
In the example below (system error message 022) each individual digit appears for
0.5 seconds. The hyphen marks the start of
the 3-digit error message
E.0.2.2.-.E.0.2.2. - .......
4.6.2 Error coding
The first digit indicates where the error has occurred; the two-digit code that fol-
lows classifies the error.
Tab. 7.22: Overview of error localization
The following overview of error messages contains the error code and a column
with the description of the error.
Tab. 7.23: Mainboard error messages
Code Description
E-1xx Mainboard error
E-2xx (unused)
E-3xx (unused)
E-4xx Error during software version transfer
E-5xx Self-test error
E-6xx Data transmission error
Identification Error description Error handling
105 RESA not responding Replace mainboard
106 Clock cannot be adjusted Replace mainboard
107 Clock not working Replace mainboard
108 EIM not responding Replace EIM card
109 EIM defective Replace EIM card