Errors that concern partial functions overwrite the standard output of the main-
board's 7-segment display for 10 seconds. Errors that lead to a restart are dis-
played permanently.
Error messages are characterized by the letter E (= error), followed by a three-digit
error code. The individual digits appear one after the other on the single-digit sta-
tus display of the mainboard (7-segment display with decimal point).
In the example below (system error message 022) each individual digit appears for
0.5 seconds. The hyphen marks the start of
the 3-digit error message
E.0.2.2.-.E.0.2.2. - .......
4.6.2 Error coding
The first digit indicates where the error has occurred; the two-digit code that fol-
lows classifies the error.
Tab. 7.22: Overview of error localization
The following overview of error messages contains the error code and a column
with the description of the error.
Tab. 7.23: Mainboard error messages
Code Description
E-1xx Mainboard error
E-2xx (unused)
E-3xx (unused)
E-4xx Error during software version transfer
E-5xx Self-test error
E-6xx Data transmission error
Identification Error description Error handling
105 RESA not responding • Replace mainboard
106 Clock cannot be adjusted • Replace mainboard
107 Clock not working • Replace mainboard
108 EIM not responding • Replace EIM card
109 EIM defective • Replace EIM card