Ascotel IntelliGate 2025/2045/2065
954 Operations supervision Part 7
4.6.13 Malfunctions of the DECT charging bays
Office 135
Tab. 7.41: Malfunctions of the DECT charging bay
43 LMAC Initiated
Release of Original
Bearer
a) Disconnection
or
a) Go back to obtain a recall
b) Connection cannot be set up
(e.g. due to a hanging link)
or
b) Try again
If still unsuccessful after 6 or 7
attempts, reset radio unit or
basic system
c) Handset already logged on to sys-
tem
c) Delete subscription on handset
(in "System" menu)
Log handset back on to system
44 Failure to set up
traffic bearer
Connection cannot be set up as too
many handsets are phoning within
the same range
•Try again
If still unsuccessful after several
attempts, "Reset Handset" (nor-
mally it is enough to press key 0
with a long keystroke and switch
back on)
45 No Quiet Channel No channel available, same as code
44
Same measures as for code 44
51 DL 04 Expiry Timer (on handset) has expired Try again
70 Timer Expired MM timer in system has expired (dur-
ing logon)
•Try again
Error description Error cause / error handling
Handset will not charge. Connect power supply
Check batteries and replace if necessary
About the charging process:
Battery symbol on handset flashes when battery is
being charged
Check tone indicates correct contact
Code Name Error description Error handling