Ascotel IntelliGate 2025/2045/2065
Part 2 Call logging (CL) 419
PC3 format
The PC3 format has been expanded to include the fields TTA (Time to answer) and
Seq. (Sequence). However, these fields are relevant only to incoming traffic.
PC4 format
If the feature "Least Cost Routing" is used in a PBX, this format can be used to
carry out the corresponding analysis. This format features an additional field that
contains the call number actually dialled by the PBX (Least-Cost-Routing function).
Tab. 2.118: PC4 format
Data field, meaning Structure Format Length Offset
Start of data record HT 1 0
Subscriber number ttttt |- SP 5 1
Cost centre number kkkkkkkkk |- SP 9 7
Sort character oo 00 -| 2 17
Date of start of connection yymmdd 00 -| 6 20
Time of start of connection hh:mm 00 -| 5 27
Duration of connection hhHmmMss 00 -| 8 33
Primary channel group / trunk card number / net-
work interface number
1)
1)
The primary channel group is output in position "c", the trunk card number in position "bb" and the
network interface number in position "pp" (see example on page 420).
cbbpp 00 -| 5 42
DDI number ddddddddddd |- SP 11 48
Number of metering pulses iiiii 00 -| 5 60
Phone number dialled by PBX
2)
2)
If "Data protection" is configured, the last 4 digits of the number are replaced by the space character
"SP".
zzzzzzzzzzzzzzzzzzzz |- SP 40 66
Phone number dialled by subscriber
2)
zzzzzzzzzzzzzzzzzzzz |- SP 20 107
TTA (Time to Answer) iii 00 -| 3 128
Sequence number sss 00 -| 3 132
Serial number llll 00 -| 4 136
Carriage Return CR 1 140
Line Feed LF 1 141