638 Planning DECT systems Part 3
All the equipment is always duplicated. This makes for more efficient planning
within the team. The standard handsets are used for determining the field
strength. They indicate the field strength of one or more radio units in the range
from 0 to 65 dBµV. For this, the equipment switches to a look-around mode in
which the handset provides a selection of all the radio units received. Up to 4 radio
units can now be selected and measured with one another. For measurement-
related reasons this is however not recommended.
To be able to determine the transitions, it is useful to have 2 radio units in opera-
tion at the same time. In some cases you may also want to prevent the changeover
from being signalled. The handover behaviour of the standard handset is selecta-
ble.
A second handset type is also available to each planner: the test handset for set-
ting up call connections. For a call connection we need to select test radio unit A
or B.
Configuration with 1 radio unit
Fig. 3.34: Configuration with 1 radio unit
Used for:
• Terminating area at the limit of the planned supply ranges
• Miniature system
• Re-measuring the system already in operation (planning usually carried out by
1 person)