Ascotel IntelliGate 2025/2045/2065
650 Planning DECT systems Part 3
Display of min. / max. values
Fig. 3.50: Minimum and maximum RSSI values in the Measure and Re-Measure / Locked" state
Procedures for a multiple measurement
The field strength of 4 radio units simultaneously can be shown on the display
of the handset. For measurement-related reasons such a multiple measurement is
however not recommended.
Display in Look-around mode
Fig. 3.51: Measure / Look-around
1438 0s17.65
Hon 3A 41 43
haz0765aaxxb0
4
4
Minimum RSSI (longer than 30 ms), can be reset with long-click.
Long-click on 4 after accessing the ”Measure and Re-Measure / locked” state
Average RSSI (Radio Signal Strength Identification)
Current RSSI
Current carrier
Long click on 4: Return to bar indicator
Current time slot
RFPI 0 17 65
go 1/7 ¥
haz0343aaxxb0
Serial number of the system
Number of the location area
Field strength of the first selected radio unit channel [dBµV]
Identity of the radio unit
Scroll through the radio units detected
The top line shows the first of 7 detected radio units.
Measurement not yet running (press the Foxkey to start the measurement)