Ascotel IntelliGate 2025/2045/2065
Part 3 Planning DECT systems 651
Selection of an individual radio unit to measure (display 1)
Fig. 3.52: Measure / Look-around state
Selection of the radio units to measure
Fig. 3.53: Measure / Tick
Selection of multiple radio units to measure (display 2)
Fig. 3.54: Measure / Group state
Measuring multiple radio units
Fig. 3.55: Measure / Group
1015 0 17 65
1000101511
haz0348aaxxb0
• Serial number of the system
• Number of the location area
• Number of the radio unit
• Field strength of the best radio unit channel [dBµV]
• Hexadecimal representation of the full RFPI
tick.1/7 clr
haz0344aaxxa0
• This radio unit is already selected
• Press the Foxkey to select this radio unit (toggle)
65<––.––.––
1000101511
haz0349aaxxb0
• Field strength value of the first radio unit in the group
• This radio unit information is shown in the status line.
When the signal is too weak, a line is shown instead of the radio unit number.
• Hexadecimal representation of the full RFPI
65 21.43 ––
stop clr
haz0345aaxxb0
• A maximum of 4 radio units can be selected to be displayed simultaneously
with their field strength value
• This radio unit is not recognized at present (last measured value and dot are
signalled)
• Clears all ticks
• Measurement in progress (press the Foxkey to halt the measurement)