Ascotel IntelliGate 2025/2045/2065
670 Planning a private network Part 3
The best solution is to sketch out a clock propagation diagram based on the fol-
lowing pattern:
1. Enter the network systems.
2. Draw the connecting lines between the systems.
3. Determine where the clock is forwarded from and to:
– Add direction arrows to the connecting lines. Make sure no loops are cre-
ated.
– To check the arrangement, follow the path in the direction of the arrows:
If you never encounter the same system twice on the same path, you can
assume that there are no loops.
4. Define network interfaces (T2, T or S external).
5. For each system configure the network interfaces of all the trunk lines with an
incoming arrow in the clock reference table. One of these will then be chosen
as the original reference.