774 Cabling interfaces Part 4
Example 2
2 Office 30 without expansion keypad
Power requirements as per Tab. 4.34: 2 x 830 mW = 1660 mW.
Tab. 4.35 indicates:
Maximum line length for a wire diameter of 0.4 mm: 569 m
Maximum line length for a wire diameter of 0,6 mm: 1200 m
As the two terminals belong to the old system family, the greyed area of Tab.
4.35 is applied here, i. e. the permissible line length is only 640 m instead of
1200 m.
Example 3
Evaluation of an existing line installation with two partial lines:
Tab. 4.36: Existing line consisting of 2 partial lines
Conclusion: The existing line cannot be used as an AD2 bus as the permissible line
length in accordance with Tab. 4.35 is exceeded.
Installation rules
If an Ascotel DECT radio unit is used, do not connect any other system terminal
to the same AD2 bus.
Do not use any terminating resistors at the bus extremity.
Avoid using different cable cross-sections on the same bus
Use the supplied cables for connecting the terminals