Ascotel IntelliGate 2025/2045/2065
Part 4 Cabling interfaces 775
Cable Requirements
Tab. 4.37: Requirements for an AD2 bus cable
Connection sockets
Fig. 4.53: RJ45 connection, single socket
7.4.1.4 Terminals
The following system terminals can be operated on the AD2 bus:
• System terminals of the Office family
• Office Pocket Adapter
• Ascotel DECT radio unit
The terminals on an AD2 bus are addressed via a single-digit terminal selection
digit (TSD).
Example:
The address of a terminal with TSD 2 on AD2 interface 0.9 on the 2025 / 2045
mainboard is 0.9-2.
Core pairs x cores 1 x 4 or 2 x 1
Stranded yes
1)
1)
Note: max. 25 m can be crossed unstranded.
(CH: Applies also to cable type G51)
Wire diameter, core 0.4…0.6 mm
Screening recommended
Characteristic impedance < 130 Ω (1 MHz)
a
b
1
2
3
4
5
6
7
8
RJ45, 8-pin
haz0036aaena0