Ascotel IntelliGate 2025/2045/2065
Part 5 Enabling remote access 851
4.2 */# procedure for remote access
Tab. 5.5: */# procedure for remote access authorization
When remote access is enabled using procedure *754, access will automatically
be barred again once the remote configuration process has been completed. It is
possible to bar access manually using #754 before a remote configuration process
has been initiated.
Remote access can be enabled permanently using the procedure *753. To bar
access, the authorized subscriber must enter the procedure #753 manually.
The enabling or barring of remote access authorization using the */# procedure
is signalled in each case by an acknowledgement tone.
Remote access authorization can also be enabled or disabled in the AIMS Config-
uration Manager or with the System Assistant function on the Office 45, in each
case at the Operator authorization level.
Note:
In a QSIG network it is important to make sure that the authorization to
change the remote access is also denied to unauthorized PISN subscrib-
ers. Otherwise a PISN subscriber would be able to use an abbreviated
dialling number defined for the destination PINX and containing the
appropriate procedure to change the remote access authorization to the
destination PINX.
4.3 Function keys for remote access authorization
On terminals of the Office family – with the exception of Office 10, Office 20 –
the */# procedure for enabling remote access authorization can be stored under
a function key, providing the subscriber has the appropriate authorization.
The relevant LED lights up if remote access is enabled once or permanently.
The relevant LED goes off as soon as remote access is denied again, either auto-
matically or manually, using the procedure or the configuration menu or the AIMS
Configuration Manager.
Enable / bar a one-off remote access *754 / #754
Enable / bar a permanent remote access *753 / #753