Ascotel IntelliGate 2025/2045/2065
874 Function check Part 6
3.4.4 PC Operator Console Office 1550
The PC Operator application is very simple to install and test. See PC Operator
documentation.
3.4.5 Ascotel DECT
Testing the radio units
All the radio units must be installed and activated via the configuration. At least
one handset must be logged on the system.
• Is the DSP card fitted?
• Does the radio unit start up correctly?
Do the LED flash sequences during the start-up process correspond to Tab.
7.11?
• Is the radio unit active (LED check)?
Does the LED flash green at intervals of 1/8 s On, 7/8 s Off (all B channels free)?
• Is the field strength sufficient for the handsets?
– Set up an internal connection with the handset:
During the connection setup the LED first lights up orange, then green at a
rate of ½ second on, ½ second off.
– Long-click key 4;
Check the bar indicator for field strength:
4 bars = "very good", 3 bars = "good", 2 bars = "adequate",
1 bar = "poor", no bar = "no signal".
(If the bar indicator does not appear after long-click 4, the display can be
changed with further long-clicks of key 4.)
– Clear down the connection.
Testing the handsets
• Does the Hotkey work?
• Does Twin Mode and / or Twin Comfort work?
• Does the Take function work?