892 Data Maintenance Part 7
Setting
The connection parameters for a software upload are set using "PBX connection /
Setting".
• Connection parameters for local access:
– IP address of the PBX for dial-up networking connections (redundant if the
IP address has already been configured in dial-up networking; see IP config-
uration, IP setup PPP/dial-up networking server)
– Dial-up networking; information on dial-up networking (see "Settings on
the PC", page 841)
–Terminal; "Ascotel Direct PPP Connection"
• Connection parameters for dial-up access:
– IP address of the PBX for dial-up networking connections (redundant if the
IP address has already been configured in dial-up networking; see IP config-
uration, IP setup PPP/dial-up networking server)
– Dial-up networking; information on dial-up networking (see "Settings on
the PC", page 841)
– Device; ISDN card or TA connection parameter LAN
• Connection parameters for local access Xmodem port:
– Communication port number of the PC (COM1 initialization value)
– Transmission rate (initialization value 9 600)
– Number of data bits (initialization value 8)
– Party (initialization value None)
– Stop bits (initialization value 1)
– Flow control (initialization value RTS / CTS)
• Connection parameters for LAN
– IP address of the PBX for LAN connections (redundant if the IP address has
already been configured in CM under ”LAN IP configuration”)
See also:
For further information on parameter configuration see "Settings",
page 840).
2.2.3 Standard upload
Loading a PBX with new system software takes places in several phases. The
Upload Manager monitors the system software copying process from the PC to
the PBX. The PBX monitors the version transfer.