EasyManua.ls Logo

Aastra Ascotel IntelliGate 2065 - 4.1.3.4 Signal destination Event Log; 4.1.3.5 Testing the signal destination configuration

Aastra Ascotel IntelliGate 2065
1014 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Ascotel IntelliGate 2025/2045/2065
928 Operations supervision Part 7
4.1.3.4 Signal destination Event Log
When the PBX is initialized, the signal destination Event Log is automatically allo-
cated event table 4. In event table 4 the frequency for all event types (with the
exception of the event type "Too many event messages") is set on "1" and the
time period on "0". This means that all the PBX's event messages are immediately
entered in the event log.
If the signal destination event log is assigned a different event table or if event
table 4 is reconfigured, the event messages are entered in the event log in accord-
ance with the new event table or the new configuration.
The Event Log consists of four protocols:
Event messages (max. 254 entries)
System failures (max. 80 entries)
Power failures (max. 10 entries)
Card failures (max. 150 entries)
If the maximum number of entries is exceeded, the oldest entry in each case is
deleted.
These 4 Event Logs protocols are not printed out automatically; likewise, your
attention is not drawn to any incoming event message. The protocols have to be
retrieved manually in the Fault & Maintenance Manager or printed out.
See also:
Event messages entered in the protocols of the Event Logs can also be
retrieved on the Office 45 using the System Assistant function (see
"Maintenance menu on the Office 45", page 939).
4.1.3.5 Testing the signal destination configuration
To test the configuration, you can trigger a test event message via the Fault &
Maintenance Manager. The event message is signalled without any delay, directly
at the selected signal destination.
If the PBX is connected with AIMS via a TA, the test event messages will be sig-
nalled only once the connection is cleared down.