Ascotel IntelliGate 2025/2045/2065
932 Operations supervision Part 7
4.3.2 State display for cordless system
4.3.2.1 LED on the radio unit Ascotel DECT
Each SB-4 and SB-8 radio unit is equipped with 3 LEDs. The radio unit operating
state is indicated by different LED colours and flashing sequences in cycles of 1 s,
specifically by the middle LED on the SB-4 and by the two outer LEDs on the SB-
8 (separately for each AD2 bus). Each character (G, R or -) corresponds to 1/8 of
a second.
Example
During the synchronization phase GGGGRRRR the LED flashes periodically
1/2 second green, 1/2 second red.
Timeout symbol (permanently lit) Timeout for turning HEX rotary
switch
Flashing Waiting for V.24 transfer
Descending segments Loading application via V.24
Rotating segments, forming the letter
"o"
Data transfer to or from a Flash card
Letter "E" followed by a three-digit
figure and a bar (repeated)
An error with error code nnn has
occurred
2)
1)
A thorough RAM test is carried out when the HEX switch is on position 2. In this case the segments move
up and down slowly.
2)
An overview of error codes can be found in "Output of error codes in the PBX", page 943.