Ascotel IntelliGate 2025/2045/2065
Part 7 Operations supervision 935
4.4.1.1 Switch positions of the HEX rotary switch
Tab. 7.14: Functions of the switch positions
Once the servicing phase is completed, turn the HEX rotary switch back to posi-
tion 0.
4.4.1.2 Entering rotary Switch sequences using the
example of the initialization function
Rotary switch sequences triggered during startup must be entered in a particular
sequence.
Example
Tab. 7.15: Rotary switch sequences for initialization function
Starting position: PBX is in operation.
1. Turn the rotary switch to "1".
2. Press the Prog. pushbutton (see Fig. 7.1 and Fig. 7.2). Various self-tests are
carried out.
3. Wait for the digit "1" to start flashing on the 7-segment display.
4. Turn the rotary switch to position "F".
If the timeout symbol "≡" appears on the display, start again with step 1.
5. Wait for the character "F" (permanently lit) to appear on the 7-segment dis-
play.
0 Normal operation; start with simple RAM test (normally takes about approx. 3 seconds). This
test is triggered only after a restart when the 230 V mains supply to the system (Power Up) is
switched on.
2 Same as 0, except with a thorough RAM test (approx. 1 minute) followed by an indication of
the RAM size. This test is triggered only after a restart when the 230 V mains supply to the
system (Power Up) is switched on.
5 Same as 0, except that the "Installer Level" configuration mode is enabled.
(Only locally using the Office 45, Pocket Adapter or V.24; not in the case of remote mainte-
nance via ISDN.)
B Same as 0, except the installed version of the system software is displayed
(e.g.: U.0.0.9.0<Pause>U.0.0.9.0… indicates Version 0.90).
Others Reserved (same function as position 0).
1-F-0 Forces a system initialization (also possible via the menu)