System Functions and Features as of I7.9
Call logging (CL) 287
syd-0200/3.0 – I7.9 – 11.2009
Direct incoming call
Fig. 150 User A calls user B (055 555 55 50)
Tab. 113 ICL output by PINX (destination PINX)
Incoming connection via a gateway PINX
Fig. 151 User A calls user C (055 555 55 53)
NO CC SC DATE TIME DURATION CHARGES METPUL EXCH
50250 321 180598 14:56 00H01m12 1.50 00015 00101
ID1 ID2 DEST1 DEST2 TTA SEQ.NO. SERIAL NO.
022222220 0222222222 50 0023 014 1236
NO PISN number of user B.
SC External call, answered directly.
ID1 User A wants to use this CLIP to present himself. It appears on user B’s system terminal display.
ID2 Caller’s CLIP number verified by the public network. Displayed to the destination user only if no
ID1 CLIP is available
DEST 1 Nothing is entered here with ICL output.
DEST 2 50 is users B direct dial number.
PINX 1
A (022 222 22 22)
B (250)
DDI 50
haz0615aaena0
haz0617aaena0
A (022 222 22 22)
C (300)
DDI 53
PINX 1 PINX 2