Function name Signal type Signal name Description
DSTPDIS.1.2 DIR_LOOP_R Z1 Record data of bank 2 for
direction resistance, Zone Z1
DSTPDIS.1.2 DIR_LOOP_R Z2 Record data of bank 2 for
direction resistance, Zone Z2
DSTPDIS.1.2 DIR_LOOP_R Z3 Record data of bank 2 for
direction resistance, Zone Z3
DSTPDIS.1.3 DIR_LOOP_R
AR1
Record data of bank 3 for
direction resistance, Zone AR1
DSTPDIS.1.3 DIR_LOOP_R
AR2
Record data of bank 3 for
direction resistance, Zone AR2
DSTPDIS.1.3 DIR_LOOP_R Z1 Record data of bank 3 for
direction resistance, Zone Z1
DSTPDIS.1.3 DIR_LOOP_R Z2 Record data of bank 3 for
direction resistance, Zone Z2
DSTPDIS.1.3 DIR_LOOP_R Z3 Record data of bank 3 for
direction resistance, Zone Z3
DSTPDIS.1.1 FLTLOOP_XFST
AR1
Record data of bank 1 for PE-
loop reactance (1st), Zone AR1
DSTPDIS.1.1 FLTLOOP_XFST
AR2
Record data of bank 1 for PE-
loop reactance (1st), Zone AR2
DSTPDIS.1.1 FLTLOOP_XFST
Z1
Record data of bank 1 for PE-
loop reactance (1st), Zone Z1
DSTPDIS.1.1 FLTLOOP_XFST
Z2
Record data of bank 1 for PE-
loop reactance (1st), Zone Z2
DSTPDIS.1.1 FLTLOOP_XFST
Z3
Record data of bank 1 for PE-
loop reactance (1st), Zone Z3
DSTPDIS.1.2 FLTLOOP_XFST
AR1
Record data of bank 2 for PE-
loop reactance (1st), Zone AR1
DSTPDIS.1.2 FLTLOOP_XFST
AR2
Record data of bank 2 for PE-
loop reactance (1st), Zone AR2
DSTPDIS.1.2 FLTLOOP_XFST
Z1
Record data of bank 2 for PE-
loop reactance (1st), Zone Z1
DSTPDIS.1.2 FLTLOOP_XFST
Z2
Record data of bank 2 for PE-
loop reactance (1st), Zone Z2
DSTPDIS.1.2 FLTLOOP_XFST
Z3
Record data of bank 2 for PE-
loop reactance (1st), Zone Z3
DSTPDIS.1.3 FLTLOOP_XFST
AR1
Record data of bank 3 for PE-
loop reactance (1st), Zone AR1
DSTPDIS.1.3 FLTLOOP_XFST
AR2
Record data of bank 3 for PE-
loop reactance (1st), Zone AR2
DSTPDIS.1.3 FLTLOOP_XFST
Z1
Record data of bank 3 for PE-
loop reactance (1st), Zone Z1
DSTPDIS.1.3 FLTLOOP_XFST
Z2
Record data of bank 3 for PE-
loop reactance (1st), Zone Z2
DSTPDIS.1.3 FLTLOOP_XFST
Z3
Record data of bank 3 for PE-
loop reactance (1st), Zone Z3
DSTPDIS.1.1 FLTLOOP_XSND
AR1
Record data of bank 1 for PE-
loop reactance (2nd), Zone AR1
Table continues on next page
1MRS756791 A Section 2
DNP3 data mappings
630 series 21
Point List Manual