EasyManua.ls Logo

ABB AC500-eCo Series - 4.3 Guidelines of Safety

ABB AC500-eCo Series
34 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
________________________________________________________________________________________________________
AC500-eCo - 26 -
Hardware Introduction
Accessories
Type Descriptions Order Number
MC502: SD Memory Card 512 MB 1SAP180100R0001
MC503: SD Memory Card adapter 1TNE968901R0100
TK503: Programming cable USB => RS485 SUB-D, 5 m 1TNE968901R1100
TK504: Programming cable USB => RS485 Terminal block, 5 m 1TNE968901R2100
TA560: Lithium Battery 1TNE968901R3201
TA561-RTC: Real time clock 1TNE968901R3200
TA562-RS: Serial communication interface COM2, RS485, terminal block 1TNE968901R4300
TA562-RTC-
RS:
Serial communication interface COM2 with real time clock, RS485,
terminal block
1TNE968901R5210
TA563-9 9 poles terminal block for S500 I/O modules, Screw Front / Cable Side, 1TNE968901R3101
TA563-11 11 poles terminal block for S500 I/O modules, Screw Front / Cable Side, 1TNE968901R3102
TA564-9 9 poles terminal block for S500 I/O modules, Screw Front / Cable Front, 1TNE968901R3103
TA564-11 11 poles terminal block for S500 I/O modules, Screw Front / Cable Front, 1TNE968901R3104
TA565-9 8 poles terminal block for S500 I/O modules, Spring Front / Cable Front, 1TNE968901R3105
TA565-11 11 poles terminal block for S500 I/O modules, Spring Front / Cable Front, 1TNE968901R3106
TA566: Wall Mounting Accessory for AC500 CPU and S500 I/O modules 1TNE968901R3107
TA567: Option cover for AC500 CPU module 1TNE968901R3202
TA568:
5 poles terminal block for AC500 CPU power supply, Cable Front / Screw
Side
1TNE968901R3108
4.3 Guidelines of Safety
Important user information
This manual provides information for the installation and the usage of the ABB product
AC500-ECO PLC.
In no event will ABB be responsible or liable for indirect or consequential damages resulting from
the use or application of this equipment.
Solid state equipment has operational characteristics differing from those of electromechanical
equipment. Because of this difference, and also because of the wide variety of uses for solid state
equipment, all persons responsible for applying this equipment must satisfy themselves that each
intended application of this equipment is acceptable.
The examples and diagrams in this manual are included solely for illustrative purposes. Because
of the many variants and requirements associated with any particular installation, ABB cannot
assume responsibility or liability for actual use based on the examples and diagrams.
Notes in this manual
The following symbols are used to highlight points of information which are intended to ensure
the user’s personal safety and protect the integrity of the equipment in this manual. Whenever
any of the following symbols are encountered, its associated note must be read and
understood. Please always heed the information provided with them. Failure to heed
precautions can result in injury to people or damage to property.

Related product manuals