Variant B: Configuration using the fieldbus configurator software FB1131
Start the fieldbus configurator software 907 FB 1131 and select "File -> New". A window appears where
you can select a fieldbus system.
Select PROFIBUS and click on OK. Now you have to configure the master.
Select
Insert -> Master from the menu bar. The mouse pointer changes to an arrow with an 'M'. Left
click with the mouse on that position on the screen where you want to place the DP Master. Another
window appears.
In this window, select
07KT97 DPM and click on Add >> to add the selected master to the network. The
selected master is now displayed on the right-hand side of the window. You can change the default
address of the master and enter a comment in the 'Description' field.
Click on
OK and continue.