EasyManua.ls Logo

ABB ACH580 Series - Page 55

ABB ACH580 Series
257 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
46 ACH580 E-Clipse bypass and packaged drive user manual
E-Clipse bypass functions overview
Bypass Not Fault (7) [BYP NOT FLT]
If configured for Bypass Not Fault, the relay is energized during normal operation.
The Bypass Not Fault relay is de-energized when power is removed from the
system, a bypass fault has occurred or when the bypass motor overload/underload
protection has tripped. The specific nature of the fault is indicated on the bypass
control panel display.
Bypass Warning (8) [BYPASS WRNG]
If configured for Bypass Warning, the relay is energized when a bypass warning is
present. The specific nature of the warning is indicated on the bypass control panel
display. The Bypass Warning relay is de-energized during normal operation.
Drive Fault (9) [DRIVE FAULT]
If configured for Drive Fault, the relay is energized when a drive fault has occurred.
The specific nature of the fault is indicated on the drive control panel display. The
Drive Fault relay is de-energized during normal control panel.
Drive Not Fault (10) [DRV NOT FLT]
If configured for Drive Not Fault, the relay is energized during normal operation. The
Drive Not Fault relay is de-energized when power is removed from the system, or
when a drive fault has occurred. The specific nature of the fault is indicated on the
drive control panel display.
Drive Warning (11) [DRIVE WARNING]
If configured for Drive Warning, the relay is energized when a drive warning is
present. The specific nature of the warning is indicated on the drive control panel
display. The Drive Warning relay is de-energized during normal operation.
Override (12) [OVERRIDE]
If configured for Override, the relay is energized when Smoke Control Override or
Advanced Override mode is selected and de-energized in all other modes. The
Override relay is de-energized during normal operation.
Bypass Hand (13) [BYPASS HAND]
If configured for Bypass Hand, the relay is energized when the motor is running in
Bypass Mode and Hand (manual operation) is selected. The Bypass Hand relay is
de-energized when Bypass Auto or Bypass Off are selected.
Bypass Off (14) [BYPASS OFF]
If configured for Bypass Off, the relay is energized when the bypass control mode
Off is selected. The Bypass Off relay is de-energized when either Bypass Auto or
Bypass Hand are selected.
Bypass Auto (15) [BYPASS AUTO]
If configured for Bypass Auto, the relay is energized when the bypass control mode
Auto is selected. The Bypass Auto relay is de-energized when either Bypass Off or
Bypass Hand are selected.

Table of Contents

Other manuals for ABB ACH580 Series

Related product manuals