270 Parameters
80.15 PQ curve Q1 Flow rate (in cubic meters per hour) at point 1 on the PQ
performance curve.
0.00 … 32767.00
m
3
/h
Flow rate at point 1 of the PQ curve. 100 = 1 m
3
/h
80.16 PQ curve P2 Power input (in kilowatts) of pump at point 2 on the PQ
performance curve.
0.00 … 32767.00
kW
Power input of pump at point 2. 100 = 1 kW
80.17 PQ curve Q2 Flow rate (in cubic meters per hour) at point 2 on the PQ
performance curve.
0.00 … 32767.00
m
3
/h
Flow rate at point 2 of the PQ curve. 100 = 1 m
3
/h
80.18 PQ curve P3 Power input (in kilowatts) of pump at point 3 on the PQ
performance curve.
0.00 … 32767.00
kW
Power input of pump at point 3. 100 = 1 kW
80.19 PQ curve Q3 Flow rate (in cubic meters per hour) at point 3 on the PQ
performance curve.
0.00 … 32767.00
m
3
/h
Flow rate at point 3 of the PQ curve. 100 = 1 m
3
/h
80.20 PQ curve P4 Power input (in kilowatts) of pump at point 4 on the PQ
performance curve.
0.00 … 32767.00
kW
Power input of pump at point 4. 100 = 1 kW
80.21 PQ curve Q4 Flow rate (in cubic meters per hour) at point 4 on the PQ
performance curve.
0.00 … 32767.00
m
3
/h
Flow rate at point 4 of the PQ curve. 100 = 1 m
3
/h
80.22 PQ curve P5 Power input (in kilowatts) of pump at point 5 on the PQ
performance curve.
0.00 … 32767.00
kW
Power input of pump at point 5. 100 = 1 kW
80.23 PQ curve Q5 Flow rate (in cubic meters per hour) at point 5 on the PQ
performance curve.
0.00 … 32767.00
m
3
/h
Flow rate at point 5 of the PQ curve. 100 = 1 m
3
/h
80.24 HQ PQ brk point Sets the transition point between the HQ and PQ
performance curves. The PQ curve is used above this
breakpoint.
0.00 … 32767.00 m Head breakpoint between HQ and PQ curves. 100 = 1 m
80.25 Pump inlet diam The diameter of the pump inlet in meters.
0.00 … 32767.00 m Pump inlet diameter. 100 = 1 m
80.26 Pump outlet diam The diameter of the pump outlet in meters.
0.00 … 32767.00 m Pump outlet diameter. 100 = 1 m
80.27 Sensors hgt diff Defines the height difference between the inlet and outlet
pressure sensors.
0.00 … 32767.00 m Height difference. 100 = 1 m