Fault tracing 327
0302 APPL DIR CREATION
(0x6100)
Drive internal fault
Note: This fault cannot be
reset.
Contact your local ABB representative.
0303 FPGA CONFIG DIR
(0x6100)
Drive internal fault
Note: This fault cannot be
reset.
Contact your local ABB representative.
0304 PU RATING ID
(0x5483)
Drive internal fault
Note: This fault cannot be
reset.
Contact your local ABB representative.
0305 RATING DATABASE
(0x6100)
Drive internal fault
Note: This fault cannot be
reset.
Contact your local ABB representative.
0306 LICENSING
(0x6100)
Drive internal fault
Note: This fault cannot be
reset.
Contact your local ABB representative.
0307 DEFAULT FILE
(0x6100)
Drive internal fault
Note: This fault cannot be
reset.
Contact your local ABB representative.
0308 APPLFILE PAR
(0x6300)
Corrupted application file
Note: This fault cannot be
reset.
Reload application.
If fault is still active, contact your local
ABB representative.
0309 APPL LOADING
(0x6300)
Corrupted application file
Note: This fault cannot be
reset.
Reload application.
If fault is still active, contact your local
ABB representative.
0310 USERSET LOAD
(0xFF69)
Loading of user set is not
successfully completed
because:
- requested user set does
not exist
- user set is not compatible
with drive program
- drive has been switched
off during loading.
Reload.
0311 USERSET SAVE
(0xFF69)
User set is not saved
because of memory
corruption.
Check the setting of parameter 95.01 Ctrl
boardSupply.
If the fault still occurs, contact your local
ABB representative.
0312 UFF OVERSIZE
(0x6300)
UFF file is too big. Contact your local ABB representative.
0313 UFF EOF
(0x6300)
UFF file structure failure. Contact your local ABB representative.
0314 TECH LIB INTERFACE
(0x6100)
Incompatible firmware
interface
Note: This fault cannot be
reset.
Contact your local ABB representative.
0315 RESTORE FILE
(0x630D)
Restoration of backed-up
parameters failed.
Contact your local ABB representative.
0316 DAPS MISMATCH
(0x5484)
Mismatch between JCU
Control Unit firmware and
power unit logic versions.
Contact your local ABB representative.
Code
Fault (fieldbus code),
other information
Cause What to do

Table of Contents

Other manuals for ABB ACQ810