EasyManua.ls Logo

ABB ACS 311-1P1-1 - Page 16

ABB ACS 311-1P1-1
99 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8 ACS 300 User’s Manual
Chapter 1 - Overview of This Manual
Table 1-2 ACS 300 AC drive types for 50 Hz and 60 Hz supplies.
Input power supply 380 to 480 V.
1)
Allowed for one minute every ten minutes at 50°C ambient.
2)
The impedance of input power supply affects the input current.
3)
The single underline (_) in the type designation
stands for “0” or “1”.
Type
designation
3)
Frame
Rated
input
current
2)
3-phase
I
1
[A]
Output current
Maximum
permissible rated
motor power
Weight
Rated
current
I
N
[A]
Short-term
overload
current
I
OVER
[A]
1)
P
N
[Hp] P
N
[kW] [lbs] [kg]
ACS 3_1-1P6-3 R1 3.0 2.5 3.8 1 0.75 10.1 4.6
ACS 3_1-2P1-3 R1 3.9 3.2 4.8 1-1/2 1.1 10.1 4.6
ACS 3_1-2P7-3 R1 5.0 4.1 6.2 2 1.5 10.1 4.6
ACS 3_1-4P1-3 R1 7.5 6.2 9.3 3 2.2 10.1 4.6
ACS 3_1-4P9-3 R1 9.1 7.5 11.0 5 3.0 10.1 4.6
ACS 3_1-6P6-3 R1 12.1 10.0 15.0 7-1/2 4.0 10.1 4.6
ACS 3_1-8P7-3 R2 10.6 13.2 19.8 10 5.5 28.7 13.0
ACS 3_1-016-3 R2 21.0 24.0 27.0 15 11.0 28.7 13.0