ACS 300 User’s Manual 85
Appendix A - Product Conformity in EEA
EN 60204-1, October 1992, following the provisions of this
Directive with the exceptions per following Clauses of
EN 60204-1:
Machinery Directive Machinery Directive 89/392/EEC, Art. 4.2 and Annex II, Sub
B.
ACS 300 Frequency Converters including all types, as spec-
ified in User´s Manual, Table 1-1 and Table 1-2
• are intended to be incorporated into machinery to consti-
tute machinery covered by this Directive, as amended
• do therefore not in every respect comply with the provi-
sions of this Directive
• the following clauses of harmonised standards have been
applied:
Clause
5.3.1
Supply disconnecting (isolating) device
- manufacturer of the machine is responsible of the installation
- please, refer to “Disconnect Device” on page viii.
Clause
6.2.1
Protection by enclosures
- degree of protection is chosen according to the place of use
- please refer to “Environmental Limits” on page 80.
Clause
9.2.2
Stop functions
- manufacturer of the machine is responsible of the installation
- please, refer to “Emergency Stop Devices” on page viii.
Clause
9.2.5.4
Emergency stop
- manufacturer of the machine is responsible of the installation
- please, refer to “Emergency Stop Devices” on page viii.
Clause
13.3
Degrees of protection
- degree of protection is chosen according to the place of use
- please, refer to “Environmental Limits” on page 80
EN 60204-1: October 1992 with exceptions as described in the connec-
tion of Low Voltage Directive (see above)