Appendix A – ACS/ACC/ACP 604/607 Technical Data
A-28 ACx=ACS/ACC/ACP ACS/ACC/ACP 604/607 Drives
Table A-1 The EMC filtering of the ACx 600 units is marked in the type code as
follows. * dv/dt Filters + EMC Filters, ** dv/dt Filters + No EMC Filters, ** EMC Cabinet
with EMC Filters.
Use of the ACx 600 in Second Environment without EMC filtering (EN 61800-3: second
environment includes all establishments other than those directly connected to a low-
voltage power supply network which supplies buildings used for domestic purposes.)
ACS 600 Type
Type Code
Character no. EMC Filter
Selections
No EMC Filter
Selections
ACS/ACC/ACP 601
ACxxxxxxxxxxxxxxxxxxxx
20
09
ACS/ACC/ACP 604
ACxxxxxxxxxxxxxxxxxxxx
20
09
ACS/ACC/ACP 607
(55 to 630 kW)
ACxxxxxxxxxxxxxxxxxxxx
20
0, 3* 5**, 9
ACS/ACC 607
(630 to 3000 kW)
ACxxxxxxxxxxxxxxxxxxxxxxxxx...
26
1, 2*** 0,
ACS 600 MultiDrive
Supply Section
ACA63xxxxxxxxxxxxx...
16
1, 2*** 0
Drive Section
ACA610xxxxxxxxxxxx...
16
10
Low voltage
Equipment
Low voltage
Equipment
Equipment
(victim)
Supply transformer
Medium voltage network
Static shield
Point of measurement
ACx 600
Neighbouring network