What to doCauseFault / Aux.
code aux code
visible only on
assistant con-
trol panel and
drive com-
poser))
Code
(hex)
3 - AI2LessMIN1 - AI1LessMIN
4 - AI2GreaterMAX2 - AI1GreaterMAX
Check the source of the fault
(parameter 32.07 Supervision 1 sig-
nal).
Fault generated by the
signal supervision func-
tion 1.
Signal supervi-
sion 1
80B0
Check the source of the fault
(parameter 32.17 Supervision 2 sig-
nal).
Fault generated by the
signal supervision func-
tion 2.
Signal supervi-
sion 2
80B1
Check the source of the fault
(parameter 32.27 Supervision 3 sig-
nal).
Fault generated by the
signal supervision func-
tion 3.
Signal supervi-
sion 3
80B2
Check the source of the fault
(parameter 32.37 Supervision 4 sig-
nal).
Fault generated by the
signal supervision func-
tion 4.
Signal supervi-
sion 4
80B3
Check the source of the fault
(parameter 32.47 Supervision 5
signal).
Fault generated by the
signal supervision func-
tion 5.
Signal supervi-
sion 5
80B4
Check the source of the fault
(parameter 32.57 Supervision 6
signal).
Fault generated by the
signal supervision func-
tion 6.
Signal supervi-
sion 6
80B5
Check external device and paramet-
er 31.01 External event 1 source.
Fault in external device 1.External fault 19081
Check external device and paramet-
er 31.03 External event 2 source.
Fault in external device 2.External fault 29082
Check external device and paramet-
er 31.05 External event 3 source.
Fault in external device 3.External fault 39083
Check external device and paramet-
er 31.07 External event 4 source.
Fault in external device 4.External fault 49084
Check external device and paramet-
er 31.09 External event 5 source.
Fault in external device 5.External fault 59085
Informative warning. (See paramet-
er 99.13 ID run requested)
Current offset and gain
measurement calibration
will occur at next start.
Current calibra-
tion
A2A1
Diagnostics 167
EN
HI