Mechanical installation 45
vertically side by side
horizontally alone, IP21 (UL Type 1) only
Note 1: The vibration specification in section Ambient conditions on page 192
may not be fulfilled.
Note 2: In the horizontal mounting, the drive is not protected from dripping water.
Frame
size
Vertical installation side by side -
Free space
Above (a) Below (b)
1)
Between (c)
mm in mm in mm in
R1 2007.92007.9 0 0
R2 2007.92007.9 0 0
R3 2007.92007.9 0 0
R4 2007.92007.9 0 0
R5 200 7.9 200 11.8 0 0
R6 200 7.9 300 11.8 0 0
R7 200 7.9 300 11.8 0 0
R8 200 7.9 300 11.8 0 0
R9 200 7.9 300 11.8 0 0
3AXD00000586715.xls J
1)
Free space below is measured from the frame, not
from the cable box used in frames R1…R2 and
R5…R9.
a
b
a
b
c= 0
Horizontal installation - Free space
Frame
size
Above (a) Below (b)
mm in mm in
R1 200 7.9 30 1.2
R2 200 7.9 30 1.2
R3 200 7.9 30 1.2
Frame
size
Side up (c) Side down (d)
mm in mm in
R1 30 1.2 200 7.9
R2 30 1.2 200 7.9
R3 30 1.2 200 7.9
3AXD00000586715.xls J
d
c
d
c
a
b
b
a