2)
IEC
1)
Frame
size
Drive type ACS580-07-
Cu cable typeAl cable typeCu cable type
AWG/kcmil per phasemm
2
mm
2
250 MCM3x1503x120R70156A-4
300 MCM3x2403x150R70180A-4
2x2/02x(3x95)2x(3x70)R80240A-4
2x3/02x(3x120)2x(3x95)R80260A-4
2x250 MCM2x(3x185)2x(3x120)R90361A-4
2x300 MCM2x(3x240)2x(3x150)R90414A-4
1. The cable sizing is based on max. 9 cables laid on a cable ladder side by side, three ladder type trays one on top of the
other, ambient temperature 30 °C, PVC insulation, surface temperature 70 °C (EN 60204-1and IEC 60364-5-52/2001).
For other conditions, size the cables according to local safety regulations, appropriate input voltage and the load current
of the drive.
2. The cable sizing is based on NEC Table 310-16 for copper wires, 75 °C (167 °F) wire insulation at 40 °C (104 °F) ambient
temperature.Not more than three current-carrying conductors in raceway or cable or earth (directly buried). For other
conditions, size the cables according to local safety regulations, appropriate input voltage and the load current of the
drive.
Losses, cooling data and noise
NoiseHeat dissipa-
tion
Air flowDrive type ACS580-07-
IP54 (UL Type 12)IP21, IP42 (UL Type 1)
dB(A)Wft
3
/minm
3
/hft
3
/minm
3
/h
U
N
= 480 V
6724873445854036850145A-4
6724973536004127000169A-4
6733143536004127000206A-4
6538064127004718000246A-4
6549424127004718000293A-4
685868765130082414000363A-4
687600765130082414000430A-4
72835311181900111819000505A-4
72947111181900111819000585A-4
721120011181900111819000650A-4
721138614132400141324000725A-4
721372514132400141324000820A-4
711530015422620154226200880A-4
U
N
= 480 V - NEC types
6724873445854036850124A-4
6724973536004127000156A-4
6733143536004127000180A-4
6538064127004718000240A-4
6549424127004718000260A-4
685868765130082414000361A-4
687600765130082414000414A-4
Technical data 181